User Manual for Models: 755, 756, 757, 758, 767
2450 Impala Drive
Carlsbad, CA 92010-7226 USA
Tel: 1-760-438-2021
Fax: 1-800-869-7668 / 1-760-931-9189
www.myronl.com
CONDUCTIVITY
MONITOR/CONTROLLERS
Installation • Operation • Maintenance
Water Quality Instrumentation
Accuracy Reliability Simplicity
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - CONDUCTIVITY

User Manual for Models: 755, 756, 757, 758, 7672450 Impala DriveCarlsbad, CA 92010-7226 USATel: 1-760-438-2021Fax: 1-800-869-7668 / 1-760-931-9189www.

Page 2 - TABLE OF CONTENTS

SECTION 3Operating Procedures3.1 SWITCH AND INDICATOR CONTROLSThe front panel illustrations, switch and indicator operationaldescriptions have been pr

Page 3 - SECTION 1

Operating Procedures3.2 MODEL 767 STANDARD AND OPTIONAL FEATURESThis section describes the standard and optional features of theModel 767 Conductivity

Page 4 - Introduction

3.3.1 DECREASING SET POINT CONVERSIONThe alarm circuit(s) on all 750/760 Series Conductivity Monitorsare configured to trigger the alarm relay as the

Page 5 - Conductivity/ppm Ranges

SECTION 4Component Identification/Calibration and Preventive Maintenance4.1 PRIMARY COMPONENT IDENTIFICATIONAs identified in Section 3, the Conductiv

Page 6 - SECTION 2

Component Identification/Calibration and Preventive Maintenance4.2 METER MECHANICAL ZERO PROCEDURESModels 756, 757 & 767 (Analog Meters Only)STEP

Page 7 - Installation

Component Identification/Calibration and Preventive Maintenance4.3.4 MODEL 767NOTE:The following procedures are for the standard Model 767 Referto Sec

Page 8

WARRANTYAll Myron L monitors and cells have a two-year warranty. If any monitor or cell fails to function normally,return the faulty unit to the facto

Page 9

SECTION PAGE1 INTRODUCTION1.1 SCOPE...

Page 10 - SECTION 3

SECTION 1Introduction1.1 SCOPEThis manual provides the user with the necessary information toinstall, operate and maintain the Myron L Company’s

Page 11 - Operating Procedures

Introduction1.3 CONDUCTIVITY CELLSBoth 750 and 760 series conductivity models use the CS51 orCS52 Series cell. The 1.0 cell constant CS51 model isreco

Page 12

Conductivity/ppm RangesCS51 SERIES CELLS SUITABLE FOR ALL EXCEPT THOSE NOTEDSUFFIX 755 756 757 758 767TO CONTROL ANALOG ANALOG DIGITAL LG. ANALOGINSTR

Page 13 - SECTION 4

SECTION 2Installation2.1 GENERALThis section provides the recommended procedures for properlyinstalling the 750/760 Series Conductivity Monitors and c

Page 14

InstallationNOTE:The 750/760 Series Conductivity Monitors are not designed tooperate with a Cell cable length that exceeds 100' (30 meters).STEP

Page 15

Installation2.4 ELECTRICAL INSTALLATIONThe electrical installation procedures provided in this manual arecommon to all Conductivity Monitors. See Fig.

Page 16 - WARRANTY

Installation2.4.2 220 VAC CONVERSIONSTEP 1 Verify that the facility’s main AC power source is turned“OFF” or disconnected.STEP 2 Locate and remove the