AQUASWITCH
AQUASWITCH &
760-A AQUASWITCH
Operation Manual
INSTALLATION • OPERATION • MAINTENANCE
22 August 05
Water Quality Instrumentation
Accuracy Reliability Simplicity
ACCURACY • RELIABILITY • SIMPLICITY
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - AQUASWITCH

AQUASWITCHAQUASWITCH & 760-A AQUASWITCHOperation ManualINSTALLATION • OPERATION • MAINTENANCE22 August 05Water Quality InstrumentationAccuracy • R

Page 2 - TABLE OF CONTENTS

SECTION 3Operating Procedures3.1 GENERALSection 3.2 provides the operational descriptions for each of the Aquaswitch/760-A Aquaswitch switch a

Page 3 - SECTION 1

3.3 OPERATIONAL CHECKOUT PROCEDURESThe following checkout procedures are used to verify that the Aquaswitch or 760-A Aquaswitch is operating

Page 4 - *TM Huntington Alloy, Inc

SECTION 4Component Identication,Calibration and Preventive Maintenance4.1 GENERALSection 4.2 provides detailed illustrations to assist the us

Page 5 - SECTION 2

4.3 “PURGE CYCLE”. CALIBRATION PROCEDURESNOTE:The Purge Cycle trimmer adjustment screw (R2) (see Fig. 4-1) determines the time span that the

Page 6

4.4 “ALARM RESET” JUMPER ADJUSTMENTNOTE:The Aquaswitch/760-A Aquaswitch are shipped with an Alarm condition that occurs whenever the “IN USE” Bank

Page 7

4.5.3 FULL SCALE CALIBRATION PROCEDURESNOTE:Before attempting to calibrate the 760-A Aquaswitch analog meter, refer to Section 4.5.1.STEP 1 Turn OFF

Page 8

WARRANTYAll Myron L monitors and cells have a one year warranty. If any monitor or cell fails to function normally, return the faulty unit to the fact

Page 9

IMPORTANT! PLEASE READ!ADDENDUM TO USER’S MANUALAQUASWITCH 760A AQUASWITCHMost Aquaswitch users choose Myron L HP Series 24 vac valves. For this re

Page 10 - SECTION 3

Water Quality InstrumentationAccuracy • Reliability • SimplicityACCURACY • RELIABILITY • SIMPLICITYMYRON L COMPANY2450 Impala DriveCarlsbad, CA 92010-

Page 11

SECTION PAGE1

Page 12 - SECTION 4

SECTION 1Introduction1.1 SCOPEThis manual provides the necessary information to install, operate and maintain the Myron L Company’s Aquaswi

Page 13

1.2.3 HP SOLENOID PILOT VALVESDESCRIPTION: Being corrosive, ultra-pure water can be difcult to control. Myron L HP valves solve this problem by utili

Page 14

SECTION 2Installation2.1 GENERALSection 2.2 provides the user with the recommended procedures for mounting the Aquaswitch/760-A Aquaswitch and for com

Page 15

NOTE:The 760-A Aquaswitch is not designed to operate with a Cell cable length that exceeds 100' (30 meters).3 If at all possible, mount

Page 16 - SECTION 5

2.3 ELECTRICAL INSTALLATIONThe Aquaswitch and 760-A Aquaswitch require the user to follow separate electrical installation procedures. In addition, ba

Page 17 - IMPORTANT! PLEASE READ!

2.3.2 760-A AQUASWITCH MAIN AC POWERNOTE:The following procedures are to be used to install the 760-A Aquaswitch 115 VAC main power source. For the pr

Page 18 - Water Quality Instrumentation

2.3.4 PILOT VALVE SOLENOID CONNECTIONSNOTE:Section 2.3.4 provides the procedures for installing 115 VAC solenoid valves with maximum load rates of 25